What do we mean by “compliance”, and why is it important?

Several AMETEK Land instruments are used to demonstrate compliance with national or international environmental regulations. These include the 4500 MkIII opacity monitor and the FGA900 series multi-gas analyser. In this article, I will discuss what it is that distinguishes a compliance instrument from any other type.

 Lancom 4 portable gas analyserEnvironmental regulations worldwide are designed to protect human health and the natural world by limiting the amount of pollution that can be emitted from an industrial facility such as a power plant, and site operators are required to demonstrate compliance with the regulation. Smaller processes must perform periodic checks to show they are complying, and the AMETEK Land Lancom 4 portable gas analyser is well-suited to such measurements.

Larger combustion processes usually have to install a continuous emissions monitoring system (CEMS) to measure and record the concentration of pollutants emitted. To ensure high-quality, accurate measurements, regulations specify the performance and quality-control checks that are needed. Older rules, especially in the United States, would give detailed rules for how the measurement should be made. Unfortunately, such rules are inflexible and can preclude the use of newer and better measurement techniques. More recent regulations specify what must be achieved – for example an opacity limit of 20% - but delegate the details to a standard which is incorporated by reference. A standard is defined as a “document, established by consensus and approved by a recognised body, that provides, for common and repeated use, rules, guidelines or characteristics for activities or their results, aimed at the achievement of the optimum degree of order in a given context”.

Comité Européen de NormalisationIn Europe, the usual standards-making body is CEN, from the French acronym Comité Européen de Normalisation, and its standards are recognised by the European Union. In the United States, environmental standards are usually published by ASTM International, originally known as the American Society for Testing and Materials. Analysers used in CEMS are generally required to comply with either a CEN or an ASTM standard. For example, the analysers used in CEMS are generally required to comply with either a CEN or an ASTM standard. For example, the 4500 MkIII opacity monitor meets the requirements of both EN 15267 and ASTM D6216-12. ASTM International 

There are some significant differences between the approaches to compliance in Europe and the USA. Compliance with EN 15267 requires an independent type test of the instrument followed by periodic audits of AMETEK Land’s manufacturing facility. Compliance with ASTM D6216-12 is demonstrated by a series of detailed tests which are carried out at the AMETEK Land factory in Dronfield, UK and whose results are given in a lengthy test report which accompanies each instrument.

AMETEK Land 4200 plus monitorThe final thing to note is that some instruments used for compliance measurements can be used, either directly or in a modified form, for other measurements. A good example of this it the AMETEK Land 4200+ opacity monitor. It uses the same optical chassis and electronics as the 4500 MkIII, but it lacks an automatic calibration facility. Removing the additional hardware, and eliminating the extensive testing required by ASTM D6216 allow the instrument to be sold at a significantly lower price even though there is little difference in its measurement uncertainty.

For more information on our opacity and dust monitors please click here.
 

Archives

Skip Navigation Links.
Collapse 2022(23)2022(23)
Collapse September(1)September(1)
What is Background Radiation? And Why is it Important to Compensate for it?
Collapse August(3)August(3)
Thermal Imaging Accuracy for Furnace Applications
How Long Does My Lancom 4 Probe Need to Be?
Should I Choose an Air-cooled or Water-cooled Thermal Imaging Camera for my Furnace?
Collapse July(3)July(3)
Complete Open Gateways with the NIR-B-2K-Glass Thermal Imager to Have Digital 4.0 Data Exchange and SCADA
How Do I Perform an Audit on my Opacity Monitor?
Why Should You Use AMETEK Land Application Support to Choose the Right Pyrometer Instead of Purchasing Directly From the Internet?
Collapse June(4)June(4)
What Makes Stored Biomass Self-Ignite?
Optimising Fired Heaters using Thermal Imaging Solutions
Can the LWIR-640 be Used to Monitor the Refractory Condition of a Ladle?
What Are The Key Benefits of Using a SPOT Pyrometer with a SPOT Actuator?
Collapse May(3)May(3)
Reducing Energy Consumption & CO2 Emissions by using Continuous Furnace Outside Shell Monitoring with Stationary Industrial Thermal Imaging
Take a Tour Around The IMAGEPro Version 2 Software Interface
How to Set Glass Leak Alarms with the LWIR-640 Thermal Imager and Its IMAGEPro Software?
Collapse April(2)April(2)
Will a 1 µm and 3.9 µm Pyrometer or Thermal Imager Read the Same Tube Wall Temperatures (TWTs)? If Not, Which Value is Correct?
Do I Need a NOx Converter On My Flue Gas Monitor?
Collapse March(2)March(2)
How to Use the NIR-Borescope-2K with IMAGEPro-Glass in Float Furnaces
How to Monitor the Outside Condition of a Glass Furnace?
Collapse February(4)February(4)
What Are NOx and SOx and Why Are They Important?
How to Spot Damage in Modern Lime Kilns Using Thermal Surveys
How can accurate temperature and emissions monitoring improve efficiency, quality and sustainability?
What non-contact temperature measurement technologies are being implemented into actual Industry 4.0 communications within heavy industries?
Collapse January(1)January(1)
Measuring Gas Temperatures in a Boiler with the CDA Pyrometer
Expand 2021(21)2021(21)
Expand 2020(14)2020(14)
Expand 2019(15)2019(15)
Expand 2018(10)2018(10)