Skip to content

Plasma Nitriding

This treatment process uses a plasma field to harden the surface of the metal. This typically involves plasma temperatures between 420-660°C (788-1220°F). Precise measurements are important to ensure the desired level of hardening.

Plasma nitriding depends on a thermochemical process, so the correct temperature must be maintained for this reaction to occur. A non-contact measurement is required for this application, but the plasma field may obscure the metal surface. Instruments using a 1.6µm waveband will see through the plasma for an accurate reading.

A non-contact measurement which is unaffected by the plasma field provides an accurate temperature measurement for this application. This ensures the correct process temperature is maintained, supporting control of product quality.

Recommended Product - Cyclops 160L and SPOT M160.
  • Related Products +

    • AMETEK Land Fixed SPOT Non-contact Thermometers / Pyrometers - SPOT
      SPOT

      SPOT is a family of fully featured, high performance pyrometers for fixed non-contact infrared spot temperature measurements. Available in range of operating wavelengths, temperature ranges and process requirements.