FG - Glass Forehearth

AMETEK Land Fixed Spot Non-contact Thermometers / Pyrometers - FG - Glass Forehearth
A simple fibre-optic, two-wire, loop powered thermometer with 4 to 20mA output. Specifically designed to improve process control in the glass industry. 
  • Overview +


    Offering accurate, high resolution and reliable temperature measurements up to 1650°C (3000°F), the FG thermometer enables precise control of process temperatures in the glass industry.

    A simple, cost-effective alternative to tri level thermocouples for some zones measuring bulk glass temperature which is independent of glass level. FG’s highly stable temperature measurement is available in five temperature spans for maximum cross-application flexibility.

    Containing AMETEK Land’s market-leading infrared measurement within an advanced optic head, FG is easily installed in the furnace and linked by multi core fibre-optic light guide to a remotely located signal processor unit. 

    FG’s flexible design means it not only can monitor and control glass or refractory temperature in the forehearth, but also in the regenerator, tank and refinery, as well as other spot measurements required for glass production.

    SIMPLE AND COST-EFFECTIVE
    FG offers long-term, drift-free operation with no on-line calibration requirement. The signal processor unit is located away from the high temperatures at the optic head, linked by a multi core fibreoptic light guide.

    EASY TO INSTALL
    The two-wire 4-20mA current loop system makes the FG simple to install. A versatile adjustable mounting assembly, complete with quick release adapter and air purge, provides ease of installation and removal for inspection purposes.

    HIGHLY FLEXIBLE MEASUREMENT
    In addition to monitoring and controlling glass or refractory temperatures, FG can monitor and safeguard vulnerable refractory materials such as the crown, detect possible firing imbalance at the port arch, and give improved control of bulk glass temperatures.

    FG is AMETEK Land’s simple, cost-effective solution for temperature measurement in glass production.

     

  • Specifications +


    Measurement Ranges 
    Model  Temperature Range
    FG 9.8/13C  980 to 1300 °C 
    FG 18/24F  1800 to 2400 °F 
    FG 10/14C  1000 to 1400 °C 
    FG 12/16.5C  1200 to 1650 °C 
    FG 22/30F  2200 to 3000 °F 
    Accuracy
       Interchangeability  ±2 °C / 4 °F 
       Resolution 0.1 °C 
       Linearisation Conformity <0.5° 
       Temperature Coefficient <0.04 °C / °C - mid span 
    <0.07 °C / °C - extremities 
       Absolute 5 °C 
    General Specifications
       Output 4 to 20 mA (linear) 
       Response Time 0.5 s (to 98%) 
       Spectral Response 0.7 to 1.0 µm 
       Emissivity 0.10 to 1.00 adjustable
    (factory set to 1.00) 
       Field of View 100:1 + 10 mm/0.4 in 
    Dimensions
       Processor 160 x 75 x 55 mm / 6.3 x 2.9 x 2.2 in 
       Optic Head 106.5 x ∅ 18.5 mm / 4.2 x ∅ 0.7 in 
    Ambient Temperature Limits
       Optic Head 200 °C / 400 °F 
       Light Guide 175 °C / 350 °F 
       Processor 10 to 60 °C / 50 to 140 °F 
    Power 
       Power Requirement 24V d.c. (nominal)
    18 to 40V d.c. 
       Over Voltage Protection 250V a.c. 
    MODEL_FG/0212